FOKS SPIRIT - FKPV
In places where FOKS CLOUD convectors are not recommended in terms of their performance, FOKS SPIRIT convectors designed with a tangential fan and optimized convection are installed. FPKV convectors are placed in rooms where there are higher temperature losses. The speed of rotation of the fan can be changed depending on the temperature in the room, which allows the convector to react flexibly to temperature changes.
RICH VARIETY OF ral COLORS
Main characteristics
- PRODUCT CODE:
- FPKV
- FUNCTION:
- Heating
- FAN:
- Yes
- HEATING OUTPUT (W):
- 80-7900
- LENGTH (MM):
- 800-2800
- WIDTH (MM):
- 200,280,340
- HEIGHT (MM):
- 70,90,110
- Warranty:
- 12 months
Technical information
Prices and features
ORDER CODE
FPKV 200 cm / 9 cm / 28 cm - S - XXX
(Product code - Length / Height / Width - frame color - other specification)
ADDITIONAL SPECIFICATION
Frame color - “S” - silver, RALXXX (powder coated)
OPTIONAL
“-CL-”, “-CR-”, “-CLR-” - gapless modification of FPKV, FPK or PKO, “CL” left, “CR” right, “CLR”
both sides (convector is in the middle - see the scheme at page bottom)
“- N” - stainless steel canal AISI 304 (Additional charge + 13%)
“- SF” - noise isolation band (up to 4 dB decrease of fan noise level) additional charge +6%
“- R” - Pipe connection on the RIGHT side
INSTALLATION
- Pipes from left side, 1/2” F, (Right side optional)
- Positioning - heat exchanger to the window side; fan to the room side
- Recommended gap between the window and the convector 8-12 cm
- Frame of the convector has to be leveled with the final floor surface
- No gap between the bottom of the convector and the concrete should remain unfilled.
ELECTRICAL WIRING
- WAGO terminal block
- For ALL-IN an 220V 50Hz connection is necessary!!!
- Wiring with 3 wire or 6 wire cable ( 1mm2 )
- Power supply: +24VDC,-24VDC, signal 0-10VDC
STANDARD PACKAGE CONTENT
- Black powder coated steel canal (RAL 9005)
- Bi-metallic heat exchanger (Al-Cu), powder coated (RAL 9005)
- Energy saving fan (8W)
- Switch interface for easy connection of additional sensors or controllers
- Set of fixing elements
- Protective cover board
NEW GENERATION OF ENERGY SAVING FANS
- Noise level under 17dB (1st speed)
- 3-phase motor 24V DC
- Excellent parameters - max.power consumption 7/15 Watt/h (per each fan with 43/60mm
diameter) - All-black design
- Rubber silencers decreasing vibrations and noise
- Easy system of replacement
SOUNDPROOFING FOIL
The outer side of the convector canal as well as its inner part in the area under the fan is covered with soundproofing foil. It further reduces fan noise as well as the potential transmission of vibrations - e.g. of joinery or metal construction. Soundproofing foil is also recommended as additional insulation when the convector is built into non-concreted structure.